Skip to content

Boston EM11T Wireless Combined Gas Analyser and Diesel Smoke Meter

Boston EM11T is our combined Gas Analyser and Diesel Smoke Meter emissions package. Comprising two separate stands, our GCP3 mobile PC stand and a mobile emissions module trolley, this package comes complete with our BPC-091 high specification PC, large 24″ display and wireless mouse and keyboard. The EM11T is a professional emissions package for busy MOT stations.

EM11T Wireless Combined Gas Analyser and Diesel Smoke Meter

DVSA Connected MOT Equipment Approved

The Boston EM11T is our combined Gas Analyser and Diesel Smoke Meter emissions package. Comprising two separate stands, our GCP3 mobile PC stand and a mobile emissions module trolley, this package comes complete with our BPC-091 high specification PC, large 24″ display and wireless mouse and keyboard. The EM11T is a professional emissions package for busy MOT stations.

Wireless Combined Gas Analyser and Diesel Smoke Meter

DVSA Connected MOT Equipment Approved

The Boston EM11T is our combined Gas Analyser and Diesel Smoke Meter emissions package. Comprising two separate stands, our GCP3 mobile PC stand and a mobile emissions module trolley, this package comes complete with our BPC-091 high specification PC, large 24″ display and wireless mouse and keyboard. The EM11T is a professional emissions package for busy MOT stations.

With the added benefit of Bluetooth wireless connectivity, the compact gas and smoke modules can locate neatly at the end of the test lane, whilst the GCP3 control system can be positioned virtually anywhere convenient – total flexibility and a big advantage in any workshop. With the addition of RFC-96, our Bluetooth 5 (LE) remote control, both models can be controlled remotely from inside the vehicle.

Approved in nearly all European countries to the highest and latest specifications, the OPA100 and AGS200 are small and lightweight, and are one of the most advanced and best selling emissions testing packages in the market today.

Both the OPA and AGS can complete a FAST PASS diesel test and a Basic Emissions Test (BET) in under 3.5 minutes respectively, including printed results (if required).

The package also contains our new EOBD-400, a Bluetooth 5 (LE) EOBD diagnostic interface for communication of the Oil Temperature and RPM directly back to the control software, SW900 iV. Furthermore, EOBD-400 is also able to carry out diagnostic interrogation using many off-the-shelf third party applications (Android and iOS), providing useful additional benefits.

Our SW900 iV control software is developed and written by Boston here in the UK, specifically for the operation of our computer driven products. It contains many novel features not found in other control software, just a few of which are shown below:

  • Seamless integration with the DVSA MTS work-order system.
  • Connects to all Boston products; gas and diesel emissions testers, roller brake testers, decelerometers, headlight testers, cameras, our EOBD-400 diagnostic interface and more.., everything is controlled from one software.
  • Flexible printout options.
  • Option to send a ‘Help Request’ message direct to our service department, no phone call or emails needed.
  • Built-in remote assistance allows our support team to connect in seconds if necessary.
  • Send test results direct to customers via email.
  • Automatic updates over the internet.
OPA100 Diesel Smokemeter  
Fast warm up time of 5 minutes Contamination monitoring
EOBD-400 Bluetooth diagnostic interface for RPM / Oil temperature measurement Automatic zero setting
Able to carry out the MoT FAST PASS test in under 3.5 minutes Single cable connection for power and all communication
Virtually zero maintenance RS232, RS485 and Bluetooth communication
Chamber pressure monitoring Digital and graphical display of data
Heated and automatic chamber temperature control LATEST DVSA specification approved
AGS200 Gas Analyser  
Fast warm up time of 5 minutes Ambient pressure self compensating
EOBD-400 Bluetooth diagnostic interface for RPM / Oil temperature measurement Automatic zero setting
Able to carry out the BET (Basic Emissions Test) in under 3.5 minutes Single cable connection for power and all communication
Large, easily accessible filtration assembly Automatic test facility
Virtually zero maintenance RS232, RS485 and Bluetooth communication
Chamber pressure monitoring Digital and graphical display of data
Semi-automatic vacuum system check LATEST DVSA specification approved

 

Product Code: AGS200
Product Description: OPA-200 Exhaust Gas Analyser
 Power 11-15 volt DC from PSI-60 Power Supply
Consumption 1.5A DC,
Weight 5 kg
Operating temperature 5 to 40ºc
Dimensions 200 x 140 x 430 mm
Connectivity 485 serial network link + RS232 serial link
Oil Temperature input Direct probe connection or Wireless MGT300
RPM pulse reception Direct probe connection or Wireless MGT300
Warm up time 5 minutes
Gas-in flow rate 4 L/min
CO measurement 0 to 9.99 % – Resolution 0.01
CO2 measurement 0 to 19.9 % – Resolution 0.1
HC Hexane measurement 0 to 14000 – Resolution 1
O2 measurement 0 to 25 % – Resolution 0.01
NOX measurement 0 to 5000 PPM – Resolution 10
Lambda 0.5 to 2 – Resolution 0.001

 

 Features
Automatic continuous condensation discharge
Semi-automatic leak test
Automatic flow monitoring
Automatic oxygen sensor efficiency monitoring
Automatic pressure compensation
Automatic calibration (with sample gas)

 

 Product Code: OPA100
Product Description: OPA-100 Diesel Smoke Meter
 Power 11-15 volt DC from PSI-60 Power Supply
Consumption 1A DC, 5A DC with heating system active
Weight 5 kg
Operating temperature 5 to 40ºc
Dimensions 200 x 140 x 430 mm
Connectivity 485 serial network link + RS232 serial link
Oil Temperature input Direct probe connection or Wireless MGT300
RPM pulse reception Direct probe connection or Wireless MGT300
Warm up time 5 minutes
Light source Green LED
Receiver Photoconductive diode
Opacity measurement % 0 to 99.9 % – Resolution 0.1
Opacity measurement m-1 0 to 9.99 m-1 – Resolution 0.01
RPM measurement 300 to 9990 RPM – Resolution 10 rpm
Oil Temp measurement 20 to 150 ºc – Resolution 1
Smoke Temp measurement 20 to 400 ºc – Resolution 1

 

 Features
Automatic Pressure monitoring of measurement chamber
Measuring chamber temperature stabilisation at 99ºc
Automatic monitoring of slides
Stabilisation of ambient temperature
Automatic calibration
Automatic autozero

 